Yes,
V41108 of the Endpoint uses new 4.1.1
Endpoint functionality that attempts to login to Gateway aliases if the primary
interface is unavailable (as in the case where the notebook is not attached to
the network).
In the case of this version, the Endpoint
crashes if the Gateway alias is also unavailable.
V41110 of the Endpoint fixes this problem.
We verified the problem in the lab and tested the fix.
Tivoli Support is well aware of the
problem.
Greg Bontrager
EDS Global Client Engineering - GM
248-265-9579
From: owner-tme10-XtjxT7Vmt5b1ENwx4SLHqw@xxxxxxxxxxxxxxxx [mailto:owner-tme10-XtjxT7Vmt5b1ENwx4SLHqw@xxxxxxxxxxxxxxxx] On
Behalf Of Todd J Porter
Sent: Monday, February 28, 2005
4:15 PM
To: tme10-XtjxT7Vmt5b1ENwx4SLHqw@xxxxxxxxxxxxxxxx
Subject: Fw: [tme10] 4.1.1-LCF-008
(Endpoint v41108)
We just started experiencing this problem also and are
wondering if you found anything else out.
Todd
J. Porter
|
|
"Bontrager, Greg"
<greg.bontrager-r3q2otnueiw@xxxxxxxxxxxxxxxx>
Sent
by: owner-tme10-XtjxT7Vmt5b1ENwx4SLHqw@xxxxxxxxxxxxxxxx
01/31/2005 03:47 PM
|
Please respond to
tme10-XtjxT7Vmt5b1ENwx4SLHqw@xxxxxxxxxxxxxxxx
|
|
|
To
|
"'tme10-XtjxT7Vmt5b1ENwx4SLHqw@xxxxxxxxxxxxxxxx'" <tme10-XtjxT7Vmt5b1ENwx4SLHqw@xxxxxxxxxxxxxxxx>
|
|
cc
|
|
|
Subject
|
[tme10] 4.1.1-LCF-008 (Endpint v41108)
|
|
Recently, we
implemented a 4.1.1 Framework Upgrade up to LCF Patch 008 (v41108).
Afterwards, when the Endpoint restarts (via a reboot or service restart)
on a notebook/desktop detached from the network, customers witnessed an
lcfd.exe exception pop-up error. The same error was logged in the
Application event log. This error caused us to back out of the upgrade.
Tivoli states that patch LCF 0010 fixes this
problem, but my customer will not let me proceed without details on how/what it
fixed. Has anyone seen this issue? How did it manifest itself?
It seems to be a non-consistent problem, so any information that you can
share would be helpful.
Greg
Bontrager
EDS
248-265-9579
________________________________________________________________________
This email has been scanned for all viruses by the MessageLabs SkyScan
service._______________________________________________________________
________________________________________________________________________
This email has been scanned for all viruses by the MessageLabs SkyScan
service._______________________________________________________________
This electronic message contains information from MeadWestvaco
Corporation or subsidiary companies, which may be confidential,
privileged or otherwise protected from disclosure. The
information is intended to be used solely by the recipient(s)
named. If you are not an intended recipient, be aware that
any review, disclosure, copying, distribution or use of this
transmission or its contents is prohibited. If you have
received this transmission in error, please notify MeadWestvaco
immediately at postmaster-acgFIG3GRJw0wsQ+md68IeG/Ez6ZCGd0@xxxxxxxxxxxxxxxx
_______________________________________________________________________