logo       

Ref: TEC371 Log file adapter does not send event to TEC: msg#00412

sysutils.tivoli.tme10

Subject: Ref: TEC371 Log file adapter does not send event to TEC

Hi List,,

I have TEC 371 with FP02 running on AIX. I created a ACP to monitor the
logfile. I distributed same profile to two differrent
AIX endpoint. On both EP I have same logfile. One is sending an event to
TEC and another one is not. No events are in Gateway cache or EP cache.
Both EP are going through same GW. and both EP version is 109.

Anyone has encountered similar problem? Any suggestion for troubleshooting
this problem?

Here is my .conf file.

1 # Tue Nov 30 11:43:13 2004
#
# tecad_logfile Configuration
#
EventMaxSize=4096
BufEvtPath=/etc/Tivoli/tec/cpi2log.cache
PollInterval=60
Pre37Server=no
FilterMode=IN
LogSources=/tmp/is_log
ServerLocation=@EventServer#tmr_TIVEXTPTMR *******I also tried IP address
and it did not work.
#
Filter:Class=Cpi2_Expire_Exprocess;
Filter:Class=Cpi2_Email_Emprocess;
Filter:Class=Cpi2_Asp_Dlcextp;
Filter:Class=Cpi2_Asp_App;
Filter:Class=Cpi2_Asp_Bus;
Filter:Class=Cpi2_Asp_Is;
Filter:Class=Cpi2cl_System;
Filter:Class=Cpi2_Asp_Wusr;

Here is my logfile
2004-11-29 10:49:55,947 IsEvents ERROR FATALException:
chbuxa16-testingcom.chubb.cpi.intSvc.AccessorFailure:
2004-11-29 10:49:56,947 IsEvents ERROR FATALException: chbuxa16
-testingcom.chubb.cpi.intSvc.AccessorFailure:

Here is the tracing:
Tue Nov 30 09:55:35 2004 LOW: TECIO , err 00, ibtecad/tec_io.c line
Sending event to T/EC ...

Cpi2_Asp_Is;hostname=chbuxa16;date='2004-11-29 10:49:54,947 ';msg
='IsEvents ERROR FATALException ';END
+1325 ^A
+1326 Tue Nov 30 09:55:35 2004 LOW: TECIO , err 00, ibtecad/tec_io.c
line 0318: Event filtered by tec_put_event()
+1327 Tue Nov 30 09:55:35 2004 LOW: TECIO , err 00, ibtecad/tec_io.c
line 0319: No event sent to T/EC

2 I tried TestMode =Yes
ServerLocation=/tmp/cpi2_event
I get the event in a file. The tracing file has follwoing info.

Tue Nov 30 11:24:29 2004 LOW: TECIO , err 00, ibtecad/tec_io.c line
0294: Sending event to T/EC ...

Cpi2_Asp_Is;hostname=chbuxa16;date='2004-11-29 10:49:57,947 ';msg='IsEvents
ERROR FATALException ';END
^A
Tue Nov 30 11:24:29 2004 LOW: TECIO , err 00, ibtecad/tec_io.c line
0329: Event sent to T/EC

3 I removed all Filters, the default is filtermode=out
# Tue Nov 30 14:40:26 2004
#
# tecad_logfile Configuration
#
EventMaxSize=4096
BufEvtPath=/etc/Tivoli/tec/cpi2log.cache
PollInterval=60
Pre37Server=no
LogSources=/tmp/is_log
ServerLocation=@EventServer#tmr_TIVEXTPTMR
#


Here according to trace file event is sent to TEC but nothing is in
reception log or in tec.

Tue Nov 30 14:41:27 2004 LOW: TECIO , err 00, ibtecad/tec_io.c line
0294: Sending event to T/EC ...

Cpi2_Asp_Is;hostname=chbuxa16;date='2004-11-29 10:50:17,947 ';msg='IsEvents
ERROR FATALException ';END
^A
Tue Nov 30 14:41:27 2004 LOW: TECIO , err 00, ibtecad/tec_io.c line
0329: Event sent to T/EC
Tue Nov 30 14:41:27 2004 VERBOSE: UTILS , err 00, /configuration.c line
1511: Free pointer 200bb0b8



Vina Patel
IT Infrastructure,
Tivoli Support
Chubb & Sons, Inc.
vpatel@xxxxxxxxx




<Prev in Thread] Current Thread [Next in Thread>