Hi guys,

I am doing a Riks analysis. I print out the deflected nodes at each increment.
I guess Abaqus takes into account these deflections when Viewer plots the
deflected model.
The documentations says: if I want a solution at a particular load, I should
Restart the analysis with a non-Riks analysis. But having already the print out
of deflected nodes and the value of Load proportionality factor (which is max
1) in each increment, doesn't that giving me the deflected shape?

I appreciate any help.

Cheers,

Narcis


---------------------------------