unless you have free hotswap SCSI bays available, adding another
software raid will have to mean another box with iet.
but raid5 can not dynamic add disk and expand size right?
no, hence the need for lvm...but at the same time, lvm does not tolerate
disk loss.
so that is why i am thinking lvm on top of several raid5 or 1
where the raid5/1 is composed of devices that are available through iscsi.
At same blinking time, lvm does not tolerate losing physical volumes so
if a iet box goes down....
iet is on top of lv, so even iet box crash, hopefully lvm is still
there.
you still need lvm on the database box itself to do dynamic resizing.
why? i resize the lv iet exports and then ini side see new size scsi
disk.
this does not work. you cannot just resize a device. this will drive the
kernel/filesystem on the initiator side nuts.
very murky this one
:P any suggestion?
i had a hard think on this one...linux lvm don't do fault tolerance but
md does...so where do you use these pieces on the initiator box and or
the target box and how to combine them is a bit sketchy at the moment.
we need a complete solution...
which comes down to multiple iet boxes. iet locally raided for
redundancy. then the initiator box will have to use raid on multiple iet
exported devices and treat those as a PV for the initiator LVM. Adding
to the VG will mean adding a set of iet boxes.
-------------------------------------------------------