Aha, interesting...
On the other hand, the drives on the storage blade that are connected
through a highpoint raid card, give smart_ Munin temperature readings
as actual temperature (see log below) that are consistent with the
hddtemp_smartctl plugin. I'm a bit confused.. is this supposed to work
this way?
Thanks,
Andrey.
root@storage02:~# smartctl -d hpt,1/1 -A /dev/sda
smartctl version 5.37 [i486-pc-linux-gnu] Copyright (C) 2002-6 Bruce
Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF READ SMART DATA SECTION ===
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 120 085 006 Pre-fail
Always -
242393951
3 Spin_Up_Time 0x0003 093 093 000 Pre-fail
Always -
0
4 Start_Stop_Count 0x0032 100 100 020 Old_age
Always -
7
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail
Always -
0
7 Seek_Error_Rate 0x000f 070 060 030 Pre-fail
Always -
10864720
9 Power_On_Hours 0x0032 100 100 000 Old_age
Always -
305
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail
Always -
0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age
Always -
11
187 Unknown_Attribute 0x0032 100 100 000 Old_age
Always -
0
189 Unknown_Attribute 0x003a 100 100 000 Old_age
Always -
0
190 Temperature_Celsius 0x0022 070 063 045 Old_age
Always -
521863198
194 Temperature_Celsius 0x0022 030 040 000 Old_age
Always -
30 (Lifetime Min/Max 0/26)
195 Hardware_ECC_Recovered 0x001a 070 055 000 Old_age
Always -
63640338
197 Current_Pending_Sector 0x0012 100 100 000 Old_age
Always -
0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age
Offline -
0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age
Always -
0
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age
Offline -
0
202 TA_Increase_Count 0x0032 100 253 000 Old_age
Always -
0
Nicolas STRANSKY wrote:
Le 12/13/2006 09:18 PM, it a écrit :
Hello,
I'm looking at the graphs from far away and wondering, is our server
going to have a meltdown, or is it just a misreading on the plugin part.
I hope it's the latter.. looks like it anyway ;)
So, down to the problem:
smart_ plugin is reading stable temperatures of 121 on sda, while
hddtemp_smartctl plugin is reading a stable 26-28. Any ideas why?
Here's the hddtemp output from smartctl:
194 Temperature_Celsius 0x0022 121 093 000 Old_age
Always - 26
Is hddtemp_smartctl reading the last value and smart_ the first?
Yes.
Have a look at the remarks, here:
http://munin.projects.linpro.no/wiki/plugin-smart_
|
-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV_______________________________________________
munin-users mailing list
munin-users@xxxxxxxxxxxxxxxxxxxxx
https://lists.sourceforge.net/lists/listinfo/munin-users